Show enclosure powersupply – HP Onboard Administrator User Manual
Page 125
Enclosure management commands 125
-------
= 1314
Interconnect Bay Power Summary:
Bay Name Power Allocated (Watts DC)
--- -------------------------------- --------------------------
1 GbE2c Ethernet Blade Switch 25
2 0
-------
= 25
Fan Power Summary:
Total Fans Fan Rule Present Power Power Allocated
(Number of Fans) (Number of Fans) (Watts DC) (Watts DC)
---------------- ---------------- -------------- ---------------
6 6 148 480
SHOW ENCLOSURE POWERSUPPLY
•
Command:
SHOW ENCLOSURE POWERSUPPLY {ALL | <power supply number> [{ , | - } <power
supply number>]}
•
Description:
Displays:
o
Power supply status
o
AC input status
o
Capacity
o
Input voltage range #1 (measured in V)
o
Input voltage range #2 (if necessary; measured in V)
o
Input frequency range (measured in Hz)
o
Part number
o
Serial number
o
Hardware revision for the specified power supply (if one is specified)
o
Range of power supplies, or for all power supplies (if ALL is specified).
•
Access level/Bay level:
All
•
Restrictions:
None
•
Example:
OA-0018FE27577F> show enclosure powersupply 1
Power Supply #1 Information:
Status: OK
AC Input Status: OK
Capacity: 1200 Watts
Current Power Output: 590 Watts
Serial Number: 531300ALL00233
Product Name: HP PROLIANT SERVER PS
Part Number: 438203-001