HP Onboard Administrator User Manual

Page 165

Advertising
background image

Blade management commands 165

SHOW SERVER TEMP {ALL | <bay number> [{ , | - } <bay number>]}

Description:
Displays the temperature sensor information for a specified server blade or range of server blades

Access level/Bay level:
All
Bay specific

Restrictions:

o

You must have access to the specified bay number.

o

Different sides of the server bay cannot be designated within the same range.

Example:

OA-0018FE27577F> SHOW SERVER TEMP ALL

Device Bay #1 Temperature Information

Locale Status Temp Caution

Critical

----------------------------------- ------ -------- -------

--------

Memory Zone OK 37C/ 98F 81C 86C

CPU Zone OK 30C/ 86F 70C 75C

CPU 1 OK 34C/ 93F 95C 100C

CPU 1 OK 34C/ 93F 95C 100C

Ambient Zone OK 20C/ 68F 38C 43C

CPU 2 OK N/A

CPU 2 OK N/A

Virtual Fan: 37%

Device Bay #2 Temperature Information

Locale Status Temp Caution

Critical

----------------------------------- ------ -------- -------

--------

Memory Zone OK 44C/111F 81C 86C

CPU Zone OK 39C/102F 70C 75C

CPU 1 OK 58C/ 0F 95C 100C

CPU 1 OK 58C/ 0F 95C 100C

System Zone OK 26C/ 78F 40C 45C

CPU 2 OK 58C/ 0F 95C 100C

CPU 2 OK 58C/ 0F 95C 100C

Ambient Zone OK 24C/ 75F 40C 45C

Virtual Fan: 51%

Device Bay #3 Temperature Information

No Server Blade Installed

Device Bay #4 Temperature Information

Locale Status Temp Caution

Critical

----------------------------------- ------ -------- -------

--------

System Zone OK 41C/105F 80C 85C

CPU Zone OK 36C/ 96F 65C 70C

CPU 1 OK 53C/127F 95C 100C

CPU 1 OK 53C/127F 95C 100C

Advertising