Blade management commands 158

o

NICs name and slot number

o

iLO name, iLO IP address, and iLO firmware version

o

Power Management Controller version

o

VLAN ID

o

IPv6 information

o

iLO Federation capability

Access level/Bay level:
All
Bay specific

Restrictions:

o

You must have access to the specified bay number.

o

MAC and WWN information is no longer included in the output for this command with Onboard
Administrator firmware version 3.60.

o

Different sides of the server bay cannot be designated within the same range.

Example:

OA-984BE179846D> show server info 11

Server Blade #11 Information:

Type: Server Blade

Manufacturer: HP

Product Name: ProLiant BL460c G7

Part Number: 603591-B21

System Board Spare Part Number: 605659-001

Serial Number: MXQ1281CFX

UUID: 35333036-3139-584D-5131-323831434658

Server Name: host is unnamed

Asset Tag: [Unknown]

ROM Version: I27 05/05/2011

CPU 1: Intel(R) Xeon(R) CPU E5506 @ 2.13GHz (4 cores)

CPU 2: Not present

Memory: 6144 MB

FlexFabric Embedded Ethernet

Ethernet LOM:1-a 9C:8E:99:1F:CA:30

iSCSI HBA LOM:1-b 9C:8E:99:1F:CA:31

FCoE HBA LOM:1-b 10:00:9C:8E:99:1F:CA:

Ethernet LOM:2-a 9C:8E:99:1F:CA:34

iSCSI HBA LOM:2-b 9C:8E:99:1F:CA:35

FCoE HBA LOM:2-b 10:00:9C:8E:99:1F:CA:

This server does not contain any mezzanine cards

Management Processor Information:

Type: iLO3

Name: ILOMXQ1281CFX

Firmware Version: 1.50 Apr 14 2012

IP Address: 10.0.0.111

MAC Address: 9C:8E:99:17:02:1E

Power Management Controller Version: 1.6