G

PLUMBING

G - 6

WATER PUMP

Manufacturer:

Aquatec

17422 Pullman Street

Irvine, CA 92614

800 975-9995

949 225-2200

Fax 949 225-2222

www.aquatec.com

Aquajet RV Series

This revolutionary pump employs state-of-the-art electronics to automatically control

motor speed the pump actually adjusts its speed as you open and close water fixtures.

The Aquajet RVs exclusive soft start feature eliminates annoying rapid cycling, and

its exclusive 5-valve design can deliver twice the flow and pressure conventional RV

industry pumps.

(Partial Reprint. Please contact Aquatec for complete instructions.)

Please read these Operational Guidelines before operating the AQUAJET RV PUMP. If

additional help is needed, please consult the Factory.

CAUTIONS:

A.The pump is equipped with an electrical speed controller; please insure that electrical

connections are made in accordance with these instructions.

B. The pump is equipped with a pressure sensing demand switch, which controls

the maximum operating pressure as set at the Factory. Never subject the pump to

pressures above 125 PST (9.5 bars).

C. Never operate the pump in a harsh environment or hazardous atmosphere, since

motor brush and switch may cause electrical arcing.

D. Pump head materials are designed for use with water only. Do not use with

petroleum products.

E. As long as there is inlet water pressure, the pump will not stop forward flow of water

even if the motor is turned off. Be sure the system has a positive means of shutting

off water supply.

F. Always consider electrical shock hazards when working with and handling electrical

equipment. If uncertain, consult an Electrician. Electrical wiring should only be done

by a qualified Electrician per local and State Electrical Codes.

Do not subject the pump to extreme high or low (freezing) temperatures while in

operation. (Operating ambient temperature range is 32º to 115º F).

The pump will only prime if all pressure is relieved from the outlet port