HP 460 W CS Gold power supply (92% efficiency)

Specification

Value

Input requirements

Rated input voltage

100V to 240V AC

Rated input frequency

50 Hz or 60 Hz

Rated input current

5.5A to 2.2A

Rated input power

526 W at 100 V AC input

505 W at 200 V AC input

Btus per hour

1794 at 100 V AC input
1725 at 200 V AC input

Power supply output

Rated steady-state power

460 W at 100 V to 120 V AC

input

460 W at 200 V to 240 V AC
input

Maximum peak power

460 W at 100 V to 120 V AC

input

460 W at 200 V to 240 V AC
input

HP 460 W CS Platinum Plus power supply (94% efficiency)

Specification

Value

Input requirements

Rated input voltage

100V to 240V AC

Rated input frequency

50 Hz or 60 Hz

Rated input current

5.2A to 2.1A

Rated input power

509 W at 115 V AC input

495 W at 230 V AC input

Btus per hour

1764 at 100 V AC

1694 at 200 V AC

Power supply output

Rated steady-state power

460 W at 100 V to 120 V AC
input

460 W at 200 V to 240 V AC

input