Causes of errors that might occur while creating or updating a configuration file and the
recommended actions

Table 133 (page 736)

describes the causes of errors that might occur while creating or updating a

configuration file from the ISPF panel, and includes the recommended actions:

Table 133 Causes and recommended actions for an error that might occur while creating or updating
a configuration file (for the ISPF panel)

Recommended Action

Cause

Output Message

There is not enough free capacity on the device or VTOC. Check the required device
capacity and allocate a sufficient amount of free capacity.

An attempt to allocate the configuration file
failed.

YKS086E

,

YKS270E

(ALLOCATION FAILED is output in the YKS086E
message.)

The configuration file to be used is being used by another user. Make sure that the
user is a valid user.

The configuration file is being used.

(UNAVAILABLE DATASET is output in the
YKS086E

message.)

The YKS086E message displays the dataset format that causes the error and the
correct dataset format. Delete the configuration file in which the error has occurred,

The configuration file dataset format is invalid.

(DSORG, RECFM, LRECL, or BLKSIZE is output
in the YKS086E message.)

check the dataset format and the required device capacity, and then reallocate a
configuration file.

One of the possible causes is an extent allocation failure. Depending on the
configuration, the correct allocation might not be possible when allocation using a

An error occurred while editing the configuration
file by using the EXECIO TSO/E REXX
command.

YKS085E

and

YKS270E

configuration file is performed, because the system default values are used for the
amount of capacity for primary allocation and secondary allocation. In this case, take
either of the following actions:

Delete the configuration file in which an error occurred, check the dataset format
and the required device capacity, and then reallocate a configuration file.

Use CLIST ICQSPC00 to increase free capacity in the configuration file. For details
on CLIST ICQSPC00, see the TSO/E Customization.

The length of the configuration file name exceeds 44 characters.

The name of a configuration file is too long.

YKS285E

Stop creating the configuration file, and then re-create it so that the file name is no
more than 44 characters.

NOTE:

For details about the dataset format and device requirements for a configuration file, see

the HP XP7 for Business Continuity Manager Reference Guide.

What to do when an error occurs while creating a configuration file (for YKBTSCAN)

The following tables describe the causes of errors that might occur while creating or updating a
configuration file by using the YKBTSCAN, and the recommended actions.

Table 134 Causes and recommended actions for an error that might occur while creating or updating a
configuration file (for YKBTSCAN)

Recommended action

Cause

Output
message

There is not enough free capacity on the device or VTOC. Check the
required device capacity and allocate a sufficient amount of free
capacity.

An attempt to allocate the configuration
file failed.

(ALLOCATION is output in the YKS270E
message.)

YKS270E

An error occurred while renaming the configuration file to the name
displayed in dataset-name. Check whether the dataset name
displayed in dataset-name actually exists in the system.

An attempt to rename the configuration
file failed.

(RENAME, name=dataset-name is
output in the YKS270E message.)

736 Troubleshooting