Preparing hardware (3dc cascade (cnt ac-j – HP XP Racks User Manual

Page 167

Advertising
background image

Preparing hardware (3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

The following tables list the prerequisite hardware and storage system settings for using Business
Continuity Manager in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration.

Table 43 Prerequisite hardware (3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

Remarks

Description

Item

--

One host must be installed at each site.

Host

Only one storage system is allowed for
each site.

One XP P9500 disk array or XP7 storage must be installed
at each site (three storage systems are required in total).

Storage system

The paths must always be established.

Bidirectional physical path connected between appropriately
configured fibre channel ports is required between the storage
systems at the following sites:

Link between storage
systems (physical path)

Primary site and intermediate site

Intermediate site and remote site

Primary site and remote site

Table 44 Storage system setting items (3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

Remarks

Setting

Description

Item

--

Use Remote Web Console for the setup.

A journal set up for a 3DC (Cnt Ac-J Z x Cnt Ac-J Z)
configuration is required (timer type: SYSTEM or
LOCAL

).

Journal group

--

One or more journal volumes are required for each
site.

Journal volume

--

Use Business Continuity Manager for the
setup.

Command devices that can be used for the route lists
below are required (See

Table 46 (page 168)

).

Command
device

Route list required when all sites are available

Route list used when a failure occurs at a site
(recommended)

--

Use Remote Web Console or Business
Continuity Manager for the setup.

An inter-disk controller logical path (bidirectional) is
required between the following sites:

Logical path

Primary site and intermediate site

Intermediate site and remote site

Primary site and remote site

Preparing the configuration files (3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

The following table describes the configuration files required for using Business Continuity Manager
in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration.

Table 45 Required configuration files (3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration)

Remarks

Description

Item

--

Disk configuration definition files are required for the primary
site, intermediate site, and remote site.

Disk configuration
definition file

--

Prepare the following route lists by referring to

Table 46 (page

168)

:

Route list definition
file and command
device definition file

The route list that is required when all sites are available

A route list used if a failure occurs at a site (recommended)

Defining a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration

167