Troubleshooting Examples for INTFACE

the tape drives. Next, re-configure LMM with the tape drives in the correct order the
way the system saw them.

Possible Reason #2:

Another reason is that in a labeling process, OVERRIDE ON is not specified. It is
possible that the $ZSVR dismount message may contain another label than the bar-
code that LMM sees. If so, LMM will not dismount the tape due to a mismatch in the
labels. Click the OVERRIDE ON button in the Media Labeling tab on the LMM GUI
when trying to label your tapevolumes.

Troubleshooting Examples for INTFACE

Example 1

PROBLEM:

When I run the INTFACE program, control is never given back to my process...

SOLUTION:

Possible Reason #1:

Usually the problem here is that the INTFACE program is not running as a named
process.

Possible Reason #2:

Another possible problem is that the SERVER INTFACE program could have been
placed on the client.

RUN INTFACE/NAME/ <command> <any parameters needed for the command>
<procfile location>

RUN INTFACE /NAME/ EXPORT 000000 $SYSTEM.TSILMMS

RUN INTFACE /NAME/ MOUNT 000000 $TAPE1 $SYSTEM.TSILMMS