Example 2 – HP Integrity NonStop H-Series User Manual

Page 158

Advertising
background image

Troubleshooting

Library Media Manager Installation and User’s Guide529970-002

C -12

Example 2

Example 2

PROBLEM:

When I run the INTFACE Utility program, I receive a run-time error...

SOLUTION:

The most common reason for this is that the INTFACE Utility program does not know
where to find the PROCFILE file in the LMM ISV location or that LMM is not started.
You have to make sure the LMM ISV location is included on the command line and that
the LMM software is running. For example:

The 2nd parameter [$SYSTEM.OUTPUT.TAPELIST] can be any valid fully qualified
filename.

The 3rd parameter [$SYSTEM.TSILMMS] is the LMM ISV location. There has to
be a file called PROCFILE in this subvolume. If there is not a PROCFILE file in
this subvolume, then LMM is not started or you have an older version of LMM,
before the INTFACE Utility program was supported.

RUN $SYSTEM.TSILMMS.INTFACE/name/ REPORT
$SYSTEM.OUTPUT.TAPELIST $SYSTEM.TSILMMS