4.

Set the parameters. These include:

Polling Interval: The system reads all information of the specified CPEs at the interval.

Inform Interval: With periodic inform enabled, the inform interval (an integer in seconds)
is the interval at which the CPE tries to connect to the ACS and invokes the inform method.

Connection Request Username: Username that the ACS uses to initiate a connection
request to the CPE.

Connection Request Password: Password that the ACS uses to initiate a connection request
to the CPE. The password read from CPEs is a null string, rather than the actual value.

Configure the inform interval

Use this function to configure the interval at which the system polls the specified CPEs. The system
reads the configuration information of the specified CPEs at the interval, and updates the system
database.
1.

Select the Service tab, and then in the BIMS navigation tree click Resource > Batch Operate
to enter the Batch Operate page.

2.

Click Configure Inform Interval to enter the page for configuring the inform interval.

3.

Click Select CPE, and select one or more CPEs on the CPE list.

4.

Configure the inform interval.

5.

Click Apply.

Configure the polling interval

Use this function to configure the interval at which the system polls the specified CPEs. The system
reads the configuration information of the specified CPEs at the interval, and updates the system
database.
1.

Select the Service tab, and then in the BIMS navigation tree click Resource > Batch Operate
to enter the Batch Operate page.

2.

Click Configure Polling Interval to enter the page for configuring the polling interval.

3.

Click Select CPE, and select one or more CPEs on the CPE list.

4.

Configure the polling interval.

5.

Click Apply.

Configure the access parameters

Use this function to configure the interval at which the system polls the specified CPEs. The system
reads the configuration information of the specified CPEs at the interval, and updates the system
database.
1.

Select the Service tab, and then in the BIMS navigation tree click Resource > Batch Operate
to enter the Batch Operate page.

2.

Click Configure Access Parameters to enter the page for configuring the access parameters.

3.

Click Select CPE, and select one or more CPEs on the CPE list.

4.

Set the connection request username and connection request password.

5.

Click Apply.

Set the auto-restore strategy

Use this function to configure multiple CPEs in batches to automatically restore configuration or
software to the baseline version..
1.

Select the Service tab, and then in the BIMS navigation tree click Resource > Batch Operate
to enter the Batch Operate page.

2.

Click Set Auto Restore Strategy to enter the page for setting the auto-restore strategy.

Batch operations