HP OneView for VMware vCenter User Manual

Page 54

Advertising
background image

P2000/MSA2000—Port on the array controller used for this path

P9000/XP—Port number

Host Group

P4000—Name configured for the host's IQN in the management console

3PAR—Name of the host object containing the host WWN for this path

P6000 EVA—Name of the host object containing the host WWN for this path

P2000/MSA2000—Nickname of the host with the host WWN for this path

P9000/XP—Name of the host group containing the HBA WWN on the array port for
this path

Host Access

P4000—Host access level assigned to the presentation of the disk to the host (for example,
READ/WRITE or READ-ONLY)

3PAR—N/A. 3PAR storage volumes operate in a read-only/read-write configuration.

P6000 EVA—Host access level assigned to the presentation of the disk to the host (for
example, READ/WRITE or READ-ONLY)

P2000/MSA2000—Access setting for volume mapping (for example, READ/WRITE or
READ-ONLY)

P9000/XP—Host access level assigned to the volume

NOTE:

The P9000 or XP array does not allow host access to be specified on a per-host

or per-path basis.

Array Port Speed

P4000—Not applicable

3PAR—Speed at which the port is connected to the SAN (Gb/s)

P6000 EVA—Speed at which the port is connected to the SAN (Gb/s)

P2000/MSA2000

FC—Speed at which the port is connected to the SAN (Gb/s)

iSCSI—Speed at which the network port is connected to the network (Gb/s)

SAS—Speed at which the port is connected to the host or switch (Gb/s)

P9000/XP—Speed at which the port is connected to the SAN (Gb/s)

Host Mode

P4000—Not applicable

3PAR—Not applicable

P6000 EVA—Host mode assigned to the P6000 EVA host object

P2000/MSA2000—Name of the host's profile

P9000/XP—Host mode assigned to the host group

54

Using Insight Control for vCenter

Advertising