HP OneView for VMware vCenter User Manual

Page 88

Advertising
background image

6.

Save and close the file.

7.

Restart the HP Insight Control Storage Module for vCenter Service.

8.

Restart the vSphere Client.

Port conflict occurs when trying to configure P6000 Command View and MSA proxy
provider for use with Storage Module for vCenter

Possible cause: P6000 Command View and the MSA2000 G2 SMI-S proxy provider cannot coexist
on the same server because they use the same ports to communicate.

Action: If you want to manage a P6000 EVA and an MSA array with the same vCenter management
server and the Storage Module for vCenter, do not install the Storage Module for vCenter on the
P6000 Command View management server.

MSA2000 G2 or P2000 G3 MSA array information not displayed in Storage Module
GUI

Possible cause: The SMI-S service on the array might be unresponsive.

Use the following actions to solve this issue. If one action does not work, proceed to the next action.

Action: Restart the MSA2000 G2 or P2000 G3 MSA SMI-S service. This will not affect disk access.
1.

Log in to the SMU interface of the MSA2000 G2 or P2000 G3 MSA array as a user with
Manage access. Use the available management IP address (for example:
http://Management_IP_address

).

2.

Select Configuration

→Services→Management.

3.

Clear the Storage Management Initiative Specification (SMI-S) check box, and then click Apply.

4.

Select the Storage Management Initiative Specification (SMI-S) check box, and then click Apply.

The SMI-S service is now running.

5.

Refresh the Storage Module for vCenter data.

For instructions, see

“Refreshing Storage Module for vCenter data” (page 36)

.

Action 2: Restart the MSA2000 G2 or P2000 G3 MSA array management controller.

IMPORTANT:

This procedure restarts the MSA2000 G2 or P2000 G3 array controller. If you

restart a management controller, communication with it is lost until it restarts successfully . This will
not affect disk access. If the restart fails, the partner management controller remains active with
full ownership of operations and configuration information. Other applications (such as Microsoft
VSS and VDS) that rely on the management controller services might be affected.

1.

Log in to the SMU interface of the MSA2000 G2 or P2000 G3 MSA array as a user with
Manage access. Use the available management IP address (for example:
http://Management_IP_address

).

2.

Select Configuration

→System Settings→Network Interfaces.

3.

Determine which controller has the IP address used in

Step 1

.

4.

Select Tools

→Shutdown or Restart Controller.

5.

Select the following:

Operation: Restart

Controller type: Management

Controller: A or B, as determined in

Step 3

6.

Click Restart now.

7.

Log in to the SMU.

8.

Refresh the Storage Module for vCenter data.

For instructions, see

“Refreshing Storage Module for vCenter data” (page 36)

.

88