ELECTRICAL POWER

Turn on the electrical power supply

to the dryer; set all circuit breakers

to on, including the safety discon-

nect handle mounted on front of the

dryer power panel.

CONTROL POWER

SWITCH

POWER START BUTTON

Push the dryer start button, and all

the selector switches on the control

panel will be activated.

FUEL CHECK

Turn the control power switch to on.

The switch will light up. A copyright

message, model number, total run-

ning time in hours and minutes, cur-

rent date and time will appear. At this

point the controller will lock out all

other dryer functions. Once the date

and time appear, press reset and the

dryer will perform its safety circuit

check. If a fault is found, the cause

will be displayed on the LCD. If all

are found safe, the controller will sup-

ply power to the electronic fuel shut-

off valve, if so equipped, and the dry-

ing mode switch will light up, indicat-

ing that the dryer is ready to be started.

If using LP gas, make sure the tank

has plenty of fuel and that the tank

does not have a regulator mounted

to it. If using natural gas, make sure

an adequate supply is available.

If using LP gas, slowly open the

main fuel supply valve at the tank.

If using natural gas, turn on the valve

along the supply line. Then, open the

electronic shut off valve (Maxon

valve), if so equipped, or open the

manual shut off valve on the dryer

to allow fuel flow to the dryer. In-

spect all gas lines and connections

for possible leaks.

Any gas leaks must be fixed
immediately!

Moisture Control Switch-ON

Moisture Control Thermostat-MAXI-

MUM TEMPERATURE

Load Switch-OFF

Unload Switch-OFF

Fan Switches-OFF

Burner Switches-OFF

Out of Grain Timer-8 MINUTE

Load Delay-30 SECONDS

Unload Delay-30 SECONDS

Metering Roll Speed-LOW AND

HIGH SPEED SETTINGS PUT

ON ZERO

Dry Timer-60 MINUTE

Cool timer-20 MINUTE

Unload timer-10 SECONDS

Mode Switch-CONTINUOUS FLOW

The Maxon safety shut off valve.

DRYER PRE START CHECKS

PRE SEASON INSPECTION

INSPECT THE METERING

ROLLS

Open all metering roll access doors

and inspect each compartment for

any bolts, nuts or other foreign ma-

terial, that may cause possible jam-

ming of the metering rolls.

BEFORE ATTEMPTING TO

OPERATE THE DRYER MAKE

SURE ALL SAFETY SHIELDS

ARE IN PLACE, ALL BOTTOM

CLEANOUT AND REAR

ACCESS DOORS ARE CLOSED

AND ALL PERSONNEL ARE

CLEAR OF THE DRYER

SET CONTROL SWITCHES

Before the dryer is filled, thoroughly

inspect the unit and check the op-

eration of the dryer as follows.