DRYER PRE START CHECKS

iary is wired to the dryer, it should start

and rotate in the proper direction.

played. Press the dryer power stop

button to reset the panel, then press

the start button.

LOAD AUGER

ONE SPEED OPERATION

MOISTURE CONTROL

THERMOSTAT

To check the moisture control ther-

mostat leave the unloading switch

on one speed, and slowly turn down

the moisture control thermostat. As

the setting is decreased, the indica-

tor light should come on and the me-

tering rolls should stop operating.

The bottom auger will stop after the

30 second clean out delay, provid-

ing that the dryer is still being held

by the moisture control thermostat.

Rotate the moisture control thermo-

stat up to its maximum setting. The

light should go off, and the metering

rolls should restart along with the

bottom auger if it has stopped.

METERING ROLL

OPERATION

To check the metering roll operation

turn either the low speed or high speed

knob clockwise, and the metering roll

speed should increase. Turning ei-

ther knob counterclockwise will de-

With the grain supply shut off,

quickly bump the load auger switch

to manual, and see if the load auger

rotates clockwise as viewed from the

drive end, or counterclockwise if the

dryer is a front load model. If the wet

grain supply auxiliary is wired to the

dryer it should also rotate in the cor-

rect direction at this time. Turn the

load auger switch to the auto posi-

tion. The top auger and wet grain

supply auxiliary should run for one

minute, and then the dryer will shut-

down leaving the safety shutdown

message (out of grain warning) dis-

To check one speed operation

place the unload switch in the one

speed setting. Turn up the high

speed metering roll dial until the

metering rolls start rotating. The

bottom auger should rotate coun-

terclockwise as viewed from the

drive end. The metering roll drive

motor should rotate clockwise as

viewed from the drive end of the gear

box. If the dry grain take away auxil-

To check two speed operation move

the switch to the two speed position,

set low speed on 200 and high

speed on 600. Slowly turn the ther-

mostat until the moisture control

switch light comes on. The meter-

ing roll speed is now controlled by

the low speed dial. Turning the ther-

mostat the other way until the light

goes out leaves the metering rolls con-

trolled by the high speed dial.

The metering roll access area.

TWO SPEED OPERATION