Dryer start up & operation, Staged batch fan & heater switch settings – Airstream PNEG-343 User Manual

Page 22

Advertising
background image

22

matically shut down during the

cooling and unloading cycles.

11. Turn the unload switch to the

one speed position. The bottom

auger and metering rolls will

start automatically during the

unload cycle of the dry-cool-un-

load mode, along with any grain

handling equipment that is wired

to the dryer. The speed at which

the metering rolls operate during the

unload cycle is adjusted by using

the high speed metering roll knob.

Turning the dial clockwise will in-

crease the grain discharge rate, and

counterclockwise will decrease the

discharge rate.

12. To control the length of the dry

cycle using only the dry time

DRYER START UP & OPERATION

the position of the switch is cor-

rected.

14. To shutdown the dryer, close the

fuel supply valve at the fuel tank

or fuel source. If the burners are

operating, let the dryer run out

of fuel causing an automatic

shutdown due to a loss of flame.

Close the fuel valve at the dryer,

and press the dryer power stop

button. Turn off the dryer's main

circuit breaker located on the

front of the power panel. Turn

off the main power supply to the

dryer.

15. In case of an emergency, press

the dryer power stop button. The

burners, fans and all augers will

stop immediately.

setting programmed into the

system, turn the moisture con-

trol setting to off. To use the au-

tomatic moisture control so that

the dry time is determined, not

only by the dry time setting, but

also by the moisture content of

the drying grain, turn the mois-

ture control switch to on, and set

dial to a beginning setting of 135

°

F.

13. To start the drying operation

push the dryer power start but-

ton. The controller will start all

the dryer components in their

proper order. If any of the se-

lected switches are improperly

positioned for staged batch dry

ing, the display will indicate the

proper switch position, and will not

allow the dryer to operate until

STAGED BATCH FAN & HEATER SWITCH SETTINGS

Fan Setting

Auto

Auto

On

On

Fan Function

Fans stay on during dry and cool

cycle only

Fans stay on during dry and cool

cycle only

Fans are on continuously

Fans are on continuously

Heater Function

Burners stay on during dry timer cycle

only

Burners stay on during dry and cool

Burners are on continuously

Burners shut down at the end of the

dry cycle

At the end of the dry cycle in staged batch, the fans and heaters will continue running if in the Auto-Auto setting, until the

preset temperature on the moisture control thermostat is reached.

Heater Setting

Auto

On

On

Auto

Advertising