Dryer control panel – Airstream PNEG-343 User Manual

Page 9

Advertising
background image

9

DRYER CONTROL PANEL

CONTROL POWER

SWITCH

The power to the Electronic Moni-

toring Control System is turned on

or off with this switch.

The dryer service light is turned on

or off here. It also may be set on

auto, which turns the light on while

the dryer is running and off if a

shutdown occurs.

OUTSIDE LIGHT

This is used to select staged batch

or continuous flow drying. The

switch will light only after the Elec-

tronic Monitoring Control System

has been turned on, the safety cir-

cuit is okay and the reset button

on the control panel has been

pressed.

DRYING MODE SWITCH

LOAD AUGER SWITCH

FAN SWITCHES

Each fan is turned on or off with

this switch. The on position oper-

ates the fan continuously during

staged batch and continuous flow

modes. The auto position operates

the fan in staged batch during the

dry and cool cycle. The switch will

light up whenever the airflow

switch is sensing airflow and the

dryer is full of grain.

HEATER SWITCHES

Each burner is turned on or off with

this switch. The auto position op-

erates the burner in staged batch

during the dry cycle. The on posi-

tion will operate the burner only

when the fan is running. The

switch will light up only when the

flame sensor detects the flame.

UNLOAD SWITCH

The unload switch turns the meter-

ing rolls and discharge auger on or

off, and selects the operation of the

metering rolls.

• In the 2 speed position if the moisture

control switch is on, and the drying

mode switch is turned to cont. flow,

the metering roll speed will alternate

between the high speed metering roll

potentiometer setting and the low

speed metering roll potentiometer set-

ting depending on the control signal

from the moisture control thermo-

stat. The discharge auger will oper-

ate continuously.

• In the 1 speed position, if the mois-

ture control switch is on, and the dry

ing mode switch is turned to cont.

flow, the metering roll speed will op-

erate at the high speed metering roll

potentiometer setting or turn off de-

pending on the control signal from

the moisture control thermostat. The

discharge auger will operate when

ever the metering rolls are operating.

• In both the 1 speed or the 2 speed

position, if the moisture control

switch is off, and the drying mode

switch is turned to cont. flow, the

metering roll speed can be manu-

ally controlled by adjusting the

high speed metering roll potenti-

ometer. The discharge auger will

operate continuously.

• If the drying mode switch is turned

to staged batch, the unload switch

should be set to the 1 speed posi-

tion. The discharge auger and

metering rolls will only operate

during the unload cycle of the

staged batch operation, and the

speed of the metering rolls is ad-

justed using the high speed me-

tering roll potentiometer.

(Note: If the unload auxiliary

motor overload relay is being uti-

lized in the dryer control panel, this

switch will also control the opera-

tion of the auxiliary equipment.)

This is used to adjust the low speed

of the metering roll when the 2 speed

automatic moisture control feature

of the dryer is in use.

This is used to select the opera-

tion of the fill auger. In both the

auto and manual position the load

auger will operate if the dryer is low

on grain and will automatically shut

off when the dryer is full. In the auto

position only, the dryer will shut

down after a preset period of time

set on the out of grain timer, or if

grain flow is interrupted to the

dryer. The switch will light when-

ever the load auger is operating.

(Note: If the load auxiliary mo-

tor overload relay is being utilized

in the dryer control panel, this

switch will also control the opera-

tion of the auxiliary equipment).

LOW SPEED METERING

ROLL POTENTIOMETER

Advertising