Metering roll servicing service – Airstream PNEG-343 User Manual

Page 31

Advertising
background image

31

METERING ROLL SERVICING

SERVICE

adjustment as it is completely

controlled from the control box.

3. Speed reducer gear box: The

direct drive gear box provides

the required speed reduction,

and transmits power to the me-

tering rolls through a drive chain

arrangement. The gear box does

not require adjustment. The drive

chain should also be periodically

lubricated and retensioned as

necessary.

4. Unload auger time delay: The

delay controls the bottom auger

system and causes the unload

auger (and any connected aux-

iliary unloading conveyors) to

continue operating for the pro-

grammed amount of time, even

after the metering rolls stop.

This feature permits the cleanout

of grain within the unloading

equipment at the end of all dis-

charge cycles.

5. If a foreign object becomes lodged

in the metering rolls and jams

the system, the unloading auger

will stay in motion. However,

the metering roll drive will stop

and the DC motor should stall

out. The Electronic Monitoring

Control System will shut down

the dryer after a two minute

period. If any one metering roll

or sensor should malfunction

the control will display a left or

right metering roll failure warn-

ing.

The speed reducer gear box.

discharge rate for the dryer. The

maximum setting of 999 provides

a maximum 100% discharge of

1960 BPH for 1314, 2520 BPH for

1318, 3080 BPH for 1322 model

dryers.

Note: When the control is set

to the maximum discharge rate

(999), the metering roll speed

should be 17.5 RPM for 8" dis-

charge auger.

2. DC electric motor: The direct

current (DC) motor provides

the drive for the metering roll,

and is located on the front left

hand side of standard model

dryers. The output shaft of the

motor is connected directly to

the gear box assembly.The DC

motor requires no operational

1. SCR speed control: The meter-

ing roll speed pots on the front

of the control box regulate the

speed of the DC motor which

drives the metering rolls.

The markings on the scale from

0 to 999 represent the flow of

grain past the metering rolls as

a percent of the maximum grain

This dryer is equipped with SCR

metering roll drive assembly. The

metering rolls are driven by a

separate DC type electric motor.

The speed of the motor is vari-

able, and is controlled by an

electric SCR (silicon controlled

rectifier) control within the main

control box.

MAIN CONTROLS

Advertising