4 boresight adjusters, 4 boresight adjusters -6 – EOTech MIPIM (AN/PEQ-16B) - Mini Integrated Pointer Illuminator Module User Manual

Page 32

Advertising
background image

2-6

2.3 MOUNTING CONFIGURATIONS / PROCEDURES -

Continued

1. Loosen the mounting screw on the rail grabber bracket

until the jaws have sufficient space to fit over the weapon

rail.

2. Hold the MIPIM with the laser apertures facing in the

direction of the muzzle of the weapon.

3. Position the MIPIM on the rail ensuring the recoil lug is

seated in the desired recoil groove of the rail.

4. While pushing down and forward on the MIPIM, turn the

mounting screw clockwise as tightly as fingers allow.

Take note of the screw slot in the mounting screw and

using an appropriate tool (e.g., screwdriver, multipurpose

tool, etc.), turn the mounting screw an additional 3/4 turn.

2.4 BORESIGHT ADJUSTERS

The MIPIM aim lasers are co-aligned. Therefore, a single

set of adjusters moves both aiming beams. Boresighting /

zeroing can be accomplished using either the Visible or IR

Aim Laser. Table 2-1 indicates the direction of adjuster

rotation and resultant shot group movement when the MIPIM

is top mounted. Tables 2-2 and 2-3 indicate the direction of

adjuster rotation and resultant shot group movement when

the MIPIM is side mounted (left / right).

NOTE

To minimize laser travel as a result of weapon

shock, it is good practice to place a positive load

on the adjusters by ending all boresight adjuster

rotations with an approximate 1/2 turn in a CCW

direction.