2-12

2.6 ZEROING PROCEDURES

After establishing the factory preset or boresighting the

MIPIM / weapon combination, the MIPIM may be zeroed to

the weapon via live fire at a 25-meter range as described

below. Table 2-4 provides target offsets that must be

applied to the 25-meter zeroing target. Refer to Tables 2-1,

2-2, and 2-3 for adjuster rotation and resultant direction of

shot group movement.

NOTE

The Boresight Adjusters move the aiming beams

at the rate of 0.2 mrad per click. Two clicks = 1

box on a standard 25-meter zeroing target.

NOTE

Direct sunlight may hinder the ability of the user to

effectively see the Visible Aim Laser on the target.

a. On a 25-meter zeroing target, mark the designated

strike point and designated strike zone for the

weapon you are using (see Table 2-4).

b. Mount the target on an “E” silhouette or other

suitable surface at 25 meters.

c. Mount the MIPIM to the weapon.
d. Rotate the Mode Selector to the AL (IR AIM LOW)

position.

e. Activate the IR Aim Laser in continuous mode by

double-tapping the FIRE Button.

f. With the use of a night vision device, direct the IR

Aim Laser at the center of the target.