MAINTENANCE AND TROUBLESHOOTING

3.1 TROUBLESHOOTING

The procedures below will help the operator correct some of

the basic problems that may arise with the MIPIM. If an

equipment malfunction occurs that is not listed, or the tests,

inspections, and corrective actions do not resolve the

problem, refer to section 3.4 for additional guidance.

Table 3-1 Troubleshooting Procedures

Symptom

Malfunction

Corrective Action

1. Laser beam(s)

appear weak or do

not come on when

activated.

a. Software overload.

a. Cycle power.

b. Mode Switch is in the O

OFF position.

b. Turn Mode Switch to

desired position. Activate by

pressing the FIRE button.

c. Tri-Function Lens Cap is

preventing Visible Aim Laser

emission.

c. If Visible Aim Laser

emission is desired, uninstall

the Tri-Function Lens Cap.

d. Battery power is low.

d. Replace batteries.

e. Laser ports are obscured

by dirt, dust, or grime.

e. Clean laser ports. See

section 3.2.

f. Battery compartment and/or

contacts corroded.

f. Clean battery

compartment and contacts.

See section 3.2.