Table 2-6 ir illuminator pulse rates – EOTech MIPIM (AN/PEQ-16B) - Mini Integrated Pointer Illuminator Module User Manual

Page 49

Advertising
background image

2-23

2.8 USING THE LASERS - Continued

c. Release the FIRE Button. Successful programming

will be indicated by three orange flashes on the LED

Status Indicator. If programming was unsuccessful,

the LED Status Indicator will display a steady red

light for two seconds. The set pulse rate will remain

until it is programmed differently.

NOTE

To ensure successful programming, the Mode

Selector must be turned to the desired pulse rate

within 5 seconds of pressing the FIRE Button.

Table 2-6 IR Illuminator Pulse Rates

Pulse Rate

Mode Selector Position

Continuous (no pulse)

AL

1 pulse per second

DL

4 pulses per second

AH*

8 pulses per second

DH*

* The safety screw must be removed to program these pulse rates.

2.9 USING THE WHITE LIGHT ILLUMINATOR

White Light Illuminator modes of operation are selected and

activated as described in section 2.7. The White Light

Illuminator provides a beam of white light energy for visible

illumination of the intended target area. It provides for facial

recognition out to at least 25 meters.

Advertising