AT Commands

+WSPC=[lock],[nnnnnn]

C3211

lock=

0 - OTKSL(One
Time Key Sub-
sidy Lock)

1 - MSL (Master
Subsidy Lock)

nnnnnn=6 digit
unlock code

Service Programming Code

Upon successful entry of this code, all other service pro-
visioning AT commands may be used. Cingular will
provide the unlock code and type.

If an OTKSL is used to enter provisioning mode, only
the +WIMI, +WMDN, and +WCMT commands will be
allowed. All other commands will return ERROR.

Caution: This command supports five attempts to enter
the correct service programming code. If five incorrect
attempts are performed, the ME will power down.

Note: Once the correct SPC code is entered, the module
transitions to the Service Programming state. This state
is not exited until a commit is done (+WCMT). While in
the Service Programming state, subsequent validations
of the SPC code are ignored until the Service Program-
ming state is reset.

+WSSW

none

Software version of the module

+WVSS=[n]

C3211

n=roam type

0 - Home Only

1 - Automatic

2- Automatic A

3- Automatic B

Preferred Roaming List

Note: The values depend on the currently loaded PRL.

Home only - Service on home systems

For preferred systems:

Automatic - Roaming allowed on affiliated systems

For non preferred systems:

Automatic-A - Roaming allowed on affiliated systems
and any A band system

Automatic-B - Roaming allowed on affiliated systems
and any B band system

$QCVAD

C3210

n=0

n=3

n=4

The mode for answering data/fax calls with A (Answer)
or autoanswer via S0=1.

Answer as voice (Default)

Data for one call

Data for all calls

TABLE 19.

Commands Usable with PassThru

Command

Parameters

Details