Table 16. modbus settings, Modbus settings 87 – Airlink Raven GPRS User Manual

Page 95

Advertising
background image

Cingular GPRS Raven User Guide Version 2.01

87

AT Commands

Modbus, commonly used with telemetry devices, allows a connection via serial
port to the modem. See “Modbus/BSAP Configuration” on page 35.

TABLE 16.

Modbus Settings

Command

Parameters

Details

IPL=n

n=0

n=1

IP List Dial

This allows access the Modbus IP list using the first two
digits of the dial string. Example: ATDT1234567 would
go to ID "12" on the Modbus list and use the associated
IP as the destination.

Disabled

Enabled

Cannot be configured in Wireless ACE.

MDhh

hh (hex byte) =

00 - normal

01 - SLIP mode

02 - PPP mode

03 - UDP mode

04 - TCP mode

Set or query the modem's default power-up mode

When the Raven is power-cycled, it may enter the mode
specified by this command after 5 seconds. On startup,
typing ATMD0 within 5 seconds changes the mode to
normal (AT command) mode.

See also S53 to set the port for UDP or TCP.

MLISTid=d.d.d.d

id=ID
d.d.d.d=IP or
name

Enters an ID and IP address into the Modbus List. ID is
a decimal value (1 to 100).

Note: In Wireless ACE, this command (and MLISTX) is
the Addr List menu option.

MLISTXhexid=d.d.d.d

hexid=ID
d.d.d.d=IP or
name

Enters an ID and IP address into the Modbus List. ID is a
hexadecimal value (0 to 64). Note: This value is entered
via Wireless ACE as 0xHex.

MVLEN=n

n= 1 or 2

Modbus Variant ID Length

Length of the RTU ID in a modbus-variant protocol, in
bytes. This parameter is used to define the length of the
RTU ID in Modbus-like protocol data packets. This
parameter is used when the when the MD is set to hex
63.

Cannot be configured in Wireless ACE.