System Screens

On the left hand of the screen, above the control panel, is the status panel. The status panel contains four

lines of information, three of which are always displayed. The first line announces whether a SmarTrack®

model is available or not (No Model or Model Ready). The second line reports the tracking mode (Standby,

Step Track, SmarTrack®, NORAD Track, or INTELSAT Track). The third line displays alarm when alarms

are present. If any alarm is present, the alarm status is red and flashing, indicating an alarm condition has
occurred which the operator has not evaluated yet. (See

Figure 4

.) The fourth line in the status box will

appear when a Hand Held Unit is attached or when the PC is in Monitor Only mode. Control is maintained by

the Hand Held Unit or another Java application, an ADU, or M&C port. If line four is displayed, it will report in
yellow the status message Hand Held or Monitor Only. (See

Figure 5

.)

Figure 4: Home Screen - System Is Initialized

Home Screen - Hand Held Connected

Figure 5

shows the Home Screen when a Hand Held Controller device has been connected to the antenna

controller system. Whenever a Hand Held Controller device is directly connected to the antenna, the antenna

controller, from the operators PC, displays are strictly monitoring displays. Notice that the Position / Jog

screen and the Tracking screen buttons in the control panel are no longer available to the operator. All the

information displayed on the screen is still valid and will reflect all actions that are exercised by the Hand

Held Unit but the operator will not be able to make any modifications or position moves while the Hand Held

Unit is connected. The Hand Held Unit has priority. Movement icons will still be displayed to the right of the

Azimuth, Elevation, and Polarization value boxes to show when an axis is in motion.