System Screens

The pol motor type is selected from a pull down menu. The valid pol motor types are: no pol motor installed,

single speed (1:1 ratio) pol motor, and dual speed (2:1 ratio) pol motor. Refer to Table 1 to determine the

appropriate pol motor ratio.

Figure 11: Initialize Site Location Screen

Antenna Size

Polarization Drive P/N

Ratio

3.6M, 4.5M

PK5PF-100

1:1

3.7M, 5.6M Ku

PK5DRA

1:1

4.9M, 6.5M

PK65DR

2:1

7.3M, 7.6M, 8.1M, 9.3M, 9.4M

PK9DRA

2:1

Table 1: Antenna Size to Pol Motor Ratio

When the location boxes have been filled in and the antenna ID, antenna size, and pol motor type selected,

entering the NEXT button will save the information and continue initialization.

Visible Satellites Computed

Figure 12 is the second screen in the Initialization Wizard process. This screen is displayed when a valid site

location screen has been entered. This is an information-only screen and lets the operator know how many

satellites are in the current satellite table and to which hemisphere the site is located. If the hemisphere is

incorrect, he must repeat the first step and enter the correct site information. Selecting the Prev button will

allow the operator to re-enter the Site Location. Choosing the Next button will continue the Initialization

Wizard process by downloading to the PC the satellite table used for initialization. Figure 13 displays the

expected popup window that notifies the operator of the action completed. Selecting the OK button on the

popup window will continue the process.