System Screens

up or down. All four directions must be jogged to their limit and all four check boxes must be displayed

before the operator can go on to the next step in the Initialization Wizard.

Figure 15: Verify Hardware Limits Screen

Verify Pol Hardware Limits

The antenna observer used for the AZ and EL Hardware Limits verification is necessary for the Pol hardware

limits verification as well. The observer is needed to request emergency stop from the operator if any wires

or wire harnesses become entangled as the antenna moves or the antenna moves beyond its physical limits.

Single Speed Pol Drive Hardware Limits

If a single speed (1:1 ratio) pol drive is installed, the operator moves to the counter-clockwise limit as
directed by the screen. (See

Figure 16

) The operator will jog until that axis reaches the physical limit. The

operator will know that the limit is reached when that direction checkbox is checked. The operator should

also notice that the resolver counts (as displayed by the position status line) discontinue counting down.

When the pol counter-clockwise limit is reached and the operator verifies that the hardware limit is ok by

pressing the completed button, the system software will adjust the pol offset so that the counter-clockwise

limit reads 2.0 degrees.

WARNING

The observer must be in position to stop the hardware

from moving into obstructions, twisting wires, or moving

beyond physical limits.