Andrew OMACS3000 User Manual

Page 30

Advertising
background image

11-APR-06

Rev E

OMACS3000

30 of 51

System Screens

Direction

Minimum

Maxium

Az East

5 deg

175 deg

Az West

185 deg

355 deg

El Down

0 deg

40 deg

El Up

50 deg

90 deg

Pol CCW

0 deg

89.9 deg

Pol CW

90.1 deg

180.0 deg

Table 2: Software Limits Ranges

Once all of the software limits have been set and all of the check boxes have appeared, Figure 20 will be
displayed and the operator must select OK (see

Figure 21

), then next, to continue with the next initialization

step.

Figure 21: Validate Automated Software Limits

Enter Beacon Receiver Parameters


The final step in the Initialization Wizard process is the tracking parameters setup (see

Figure 22

). The

beacon slope is the multiplier used to convert the beacon receiver voltage into dBs. The beacon offset is the

value that will be added to the beacon data in order to normalize the beacon reading to 0 dB. The beacon

frequency is the frequency at which the satellite beacon is being transmitted. Note: the slope must be correct

for proper operation. It is advised that the slope be verified after initialization is completed.

Selecting the Next button after valid values have been entered will complete the initialization process and

save all the setup parameters to a file. Popup windows will notify the operator that the initialization process

is complete and that the satellite table (glblsat.tbl) was successfully downloaded from the ACS3000 server to