System Description

DS-5 STOP

Illuminates steady YELLOW when the Emergency Stop Switch is depressed.

DS-6 MICRO RESET Illuminates steady RED when MPU-17 microprocessor is in a reset condition. Blinks

RED in a continuous reset condition or buss failure.

DS-7 POWER

Illuminates steady GREEN when MC-2 is receiving +/-12 VDC

Dual VFD Motor Drive Card (MD-3)

The Dual VFD Motor Drive Card (center card) handles control, status and fault reporting of the azimuth and

elevation Variable Frequency Drive Units (VFD's). The Dual VFD Motor Drive Card has two fault indicators.

The MD-3 provides the following fault indicators that are viewable from the face of the card:

DS-1 OVERLOAD Illuminates Steady RED when AZ, EL, or both AZ and EL axis motors are drawing

excessive current. A slow RED blink (500ms) indicates loss of communication with

the MPU-17.

DS-2 FAULT

Illuminates RED when either VFD is in a fault condition. A slow RED blink (500 ms)

indicates loss of communication with the MPU-17. A fast RED blink (250 ms)

indicates both forward and reverse VFD direction commands are present

simultaneously.

Resolver To Digital Converter Card (RES-2)

The Resolver To Digital (R/D) Converter Card (right most card) is a multiplexed single converter based card

and provides resolver signal to digital bit converter. The RES-2 card accepts three resolver inputs and

outputs the 16 bit converted value of each resolver signal to the MPU-17.

The RES-2 provides the following indicators:

DS-1 EL CEN

Illuminates steady YELLOW when the EL resolver is reading center of the R/D

range (±2 degrees). A slow YELLOW blink (500 ms) indicates a loss of

communication with the MPU17. A fast (250 ms) blink indicates a loss of resolver

signal and would likely be caused by the EL resolver not being properly connected

or defective.

DS-2 AZ CEN

Illuminates steady YELLOW when the AZ resolver is reading center of the R/D

range (±2 degrees). A slow YELLOW blink (500 ms) indicates a loss of

communication with the MPU17. A fast (250 ms) blink indicates a loss of resolver

signal and would likely be caused by the AZ resolver not being properly connected

or defective.

DS-3 POL CEN

Illuminates steady YELLOW when the POL resolver is reading center of the R/D

range (±2 degrees). A slow YELLOW blink (500 ms) indicates a loss of

communication with the MPU17. A fast (250 ms) blink indicates a loss of resolver

signal and would likely be caused by the POL resolver not being properly connected

or defective.

Low Temperature Board

The low temperature board has the following indicators:

DS1 (Yellow)

High Temperature. The temperature inside the enclosure is above +50° Celsius.

DS2 (Red)

Low Temperature. The temperature inside the enclosure is at 0° Celsius. A warning

is issued. If the temperature fall below -10° Celsius power is removed from the

VFDs and all antenna movement halted. The temperature must rise above -10°

Celsius before power is restored to the VFDs.

DS3 (Green)

Power to the low temperature board is within normal limits.