Andrew OMACS3000 User Manual

Page 9

Advertising
background image

11-APR-06

Rev E

OMACS3000

9 of 51

System Description

Antenna Display Unit (Optional)

The Antenna Display Unit is a rack mountable (two rack height) antenna control unit (ADU) that is designed

to provide direct interface to a local area network to provide a remote control graphical user interface (GUI)

for the ACS3000 Antenna Control System. In addition to the rear panel interface connections, the ADU

provides a front panel mounted LCD display, keyboard, momentary action reset switch, power indicator,

summary fault alarm indicator, and display contrast adjustment allowing an alternate method for the operator

to control and determine status of the ACS3000 antenna Control System. The ADU is documented

separately in the Antenna Display Unit Users Guide.

Power/Environmental Description LMKVS-CPU

Operational Temperature:

-40 to +50° C

If heater is off internal temperature must be 0° C

before operation can begin

Storage Temperature:

-40 to +60° C

Relative Humidity:

0 - 100% Condensing

Enclosure Protection Class:

NEMA 4X / IP56

Enclosure Type:

EMI Protected Fiberglass

Control Interface Method:

Ethernet

Dimensions:

26 1/2" W x 32" H x 14" D

Weight:

88 lbs

Approvals:

EN 60950 (CE), EN 61326 Class A UL 60950, FCC

Part 15 Class A

Power:

LMKVS-CPU-208

208 - 230 VAC, 60 Amps

3 Phase 50/60 Hz

No Neutral Required, Safety Ground Required

LMKVS-CPU-380

380 - 460 VAC, 30 Amps

3 Phase 50/60 Hz

No Neutral Required, Safety Ground Required

Power/Environmental Description Beacon Interface

Operational Temperature:

0 to +50° C

Storage Temperature:

-40 to +60° C

Relative Humidity:

93 - 100% Non-Condensing

Enclosure Type:

1 RU Rack Mount Metal Enclosure

Control Interface Method:

Ethernet