Ws425 a/b nmea standard profile, Configurable parameters – Vaisala WMT700 User Manual

Page 51

Advertising
background image

Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles

VAISALA _______________________________________________________________________ 49

For example, a value of 99 signifies that all data samples were
determined to be valid and processed during the averaging time. If
some samples were determined to be "missing", these samples were
not processed and the reported signal quality is a proportional value
less than 99.

4.

Bytes 28-29 are the modulo 256 hexadecimal checksum of the
ASCII values calculated for bytes from 2 to 27.

Example:

WAP2131870503012.6014.7K99xx

Interpretation of the example message:

- Sensor

ID:

W

- Command identifier: A
- Sensor status: P = pass
- Averaged wind direction (degrees): 213
- Wind direction (degrees) @ peak wind speed: 187
- Averaging time for wind speed and direction: 05
- Averaging time for peak wind speed and direction (seconds): 03
- Averaged wind speed: 012.6
- Peak wind speed since last WA command: 014.7
- Wind speed units: K = knots
- Signal quality: 99
- Hex checksum (refer to note 4): xx

WS425 A/B NMEA Standard Profile

When the WS425 A/B NMEA Standard profile is configured, WMT700
sends messages based on the configured automatic message interval.
There are no operating commands available for the user.

Configurable Parameters

Table 14 on page 50 lists the configurable parameters and their allowed
and default values for the WS425 A/B NMEA Standard profile.