Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles

VAISALA _______________________________________________________________________ 67

aD0!

where

a

=

The single-digit WMT700 address that corresponds
to the first character of the address value.

D0

=

The send data command.

!

=

Terminates the command.

For a description of the data messages, see section SDI-12 Data
Messages on page 70.

aI! — Send Identification

This command queries WMT700 for its SDI-12 compatibility level,
model number, and firmware version number.

aI!

where

a

= The single-digit WMT700 address that corresponds to

the first character of the address value.

I

= The send identification command.

!

= Terminates the command.

The response is the following:

allccccccccmmmmmmvvvxxx . . . xxx<CR><LF>

where
a

= The single-digit WMT700 address that corresponds to

the first character of the address value.

11

= The SDI-12 version number, indicating SDI-12 version

compatibility; for example, version 1.1 is encoded as
11.

cccccccc

= An 8-character vendor identification Vaisala_

mmmmmm = 6

characters

specifying the model number of WMT700.

vvv =

3

characters

specifying

the firmware version 604.

xxx ... xxx = An optional field, up to 13 characters, used for a serial

number or other specific WMT700 information that is
not relevant for operation of the data recorder (not
used).

<CR><LF> = Terminates the response.

Advertising