Ws425 a/b ascii commands, I — identify sensor, Wx — start measurement – Vaisala WMT700 User Manual

Page 58

Advertising
background image

TECHNICAL REFERENCE___________________________________________________________

56 __________________________________________________________________ M211097EN-C

WS425 A/B ASCII Commands

Table 18 below lists the available commands for operating WMT700
with the WS425 A/B ASCII profile.

Table 18

List of WS425 A/B ASCII Commands

Command Description
I

Requests identification information for WMT700.

Wx

Starts measurement based on averaging time and fetches the data.

NOTE

The following WS425 A/B ASCII command cannot be used with
WMT700: Measurement Unit Change Ux

For a list of configuration commands for WMT700, see Vaisala
WINDCAP

®

Ultrasonic Wind Sensor Series WMT700 User's Guide.

I — Identify Sensor

This command shows the vendor, model number and version information
of WMT700.

I

Example of the command and response:

I

VAISALA WMT700 140

Wx — Start Measurement

This command starts wind measurement based on averaging time and
fetches the data automatically when the measurement has finished. You
must specify the averaging time in the command.

Averaging time supplied in the command (x) sets the averaging time for
WMT700, as if it was set with the S command. When you change the
averaging time, it applies to the next new wind value.

Wx

where
x

= Time for averaging wind speed and wind direction. The range

is from 1 to 9.