Vaisala WMT700 User Manual

Page 54

Advertising
background image

TECHNICAL REFERENCE___________________________________________________________

52 __________________________________________________________________ M211097EN-C

Table 15

Configurable Parameters for WS425 A/B NMEA
Extended Profile

Parameter Default

Value

Profile-specific Allowed
Values

Description

address

1

String with 1 character

Address for WMT700.

autoInt

1

0.25 ... 1000
Resolution: 0.25

Automatic message interval in seconds.
Do not select a message interval that is
shorter than the time it takes to send a
data message.

autoPort 1

1=COM1

port

2=COM2 port

Serial port to which WMT700 sends
automatic data messages.

autoSend

0

0 = automatic messages
disabled
19 = NMEA automatic
data message

Automatic data message number. Selects
the data message format for automatic
messages.

com1_protocol
com2_protocol
(depending on
the port used for
operating
WMT700)

0

5 = WS425 A/B NMEA
Extended

Profile for serial ports COM1 and COM2.

wndAvg

1

0.25 … 3600
Resolution: 0.25

Averaging time for wind measurement in
seconds.

wndOrientation

0

0 = array facing up
1 = array facing down

Orientation of the array of WMT700.

wndUnit

0

0 = meters per second
1 = miles per hour
2 = kilometers per hour
3 = knots

Wind speed unit.

wndVector

1

0 = scalar averaging

Wind averaging method.

To start continuous measurement, use the START command. You can
stop the measurement with the STOP command. For instructions, refer to
Vaisala WINDCAP

®

Ultrasonic Wind Sensor Series WMT700 User's

Guide.

Advertising