Bondioli&Pavesi 399CECN02_G User Manual

Page 13

Advertising
background image

13

ENG

RA - OVERRUNNING CLUTCH.

This device prevents transmission of inertial loads from implement to the

tractor during deceleration or stopping of the PTO.

Keep clear of the implement until all parts have stopped moving. Lubricate

every 50 hours of use and after storage.

SA - RATCHET TORQUE LIMITER.

This device interrupts the transmission of power when the torque exceeds

the setting.

Immediately disengage the PTO when ratcheting sounds are heard.

Lubricate every 50 hours of use and after storage.

LB – SHEAR BOLT TORQUE LIMITER.

This device interrupts the transmission of power by shearing a bolt when the

torque exceeds the setting.

Replace the sheared bolt with the same diameter, length and grade as the original.

Lubricate the LB limiters with grease fittings at least once every season and after a

period of disuse.

FRICTION TORQUE LIMITERS

When installing the device or after a storage period check the operation of the

friction plates:

• release the springs • rotate the clutch while immobilizing the PTO on which is

installed • restore the spring compression to the original value. Following seasonal

use, release the springs and store the clutch in a dry place. Check the condition

of the friction plates and restore spring compression before using the clutch. If the

clutch overheats due to frequent or prolonged slipping, consult your equipment

dealer or your local Bondioli & Pavesi representative.

FFL – FRICTION TORQUE LIMITER.

The torque transmitted to the implement is limited by allowing the clutch

plates to slip relative to each other.

Torque peaks or short duration overloads are limited when the clutch is used and

adjusted properly.

It can be used as an overload clutch, or to help start implements with high inertial

loads.

The torque setting is adjustable by adjusting the working height of the spring.

FFF - FRICTION TORQUE LIMITER

Limits torque transmission to the setting value. Do not change spring

compression as this will modify the device setting.

The torque setting of friction torque limiters FFL and FFF is adjusted by

increasing or decreasing the height “h” of the spring.

To increase / reduce the torque setting, screw / unscrew each of the eight nuts

by 1/4 of turn and check for proper operation. Repeat the procedure if necessary.

Avoid excessive tightening of the bolts - implement, tractor, or driveline damage

may occur.

26

27

28

29

30

31

Advertising