Chapter 3: Programming

Installation and Maintenance Manual

10

3.9: Clear an Existing Setpoint

A)

Unit must be in the “Program” mode.

B)

Depress

.

C)

Depress or key until setpoint to be cleared is on the display.

D)

Depress the key. Upon depression of the key, the setpoint on

the display after Step C is deleted.

E)

This keypad sequence must be completed once to clear an ON setpoint and a second time to

clear the OFF setpoint. See Section 3.8: Setpoints

CIR#

-

-

CIR ON

(Output to be Cleared)

ENT

CIR OFF

CLR SET

CLR SET

3.10: Clear All Setpoints

There are two methods of clearing all setpoints. This is accomplished as follows:

A)

Unit must be in the “Program” mode.

B)

To clear all of the setpoints in the active program, depress: .

The active program is the program currently selected using Code 771. See Section 3.7:

Setpoint Formula.

-OR-

C)

To clear all the setpoints in all programs, depress: .

CIR# - 9 - 1

ENT

ENT

CIR# - 3 - 9

-

1

-

-

NOTE: CIR# 91 and CIR# 391 only clear out programmed setpoints. They do not clear out Linear

Speed ramps or change circuits that have been selected as Linear Speed or Time-Based;

however, they will clear the setpoints programmed in these circuits.

3.11: Setpoint Availability

Every 1995 PLS has a limit on the number of setpoints that can be stored in memory. On units with the

Multiprogram option, refer to Section 3.7: Setpoint Formula to calculate the maximum amount of

setpoints available.