Installation and Maintenance Manual

Chapter 9: Specifications

9.4: DC Solid-State

(Single Pole, Normally Open)

9.5: 1995E Output Expansion Module

9.6: 1995-1446 Remote Circular Display

Maximum Load

-2 Amp DC

Load Voltage Range

-5 to 60V DC

Leakage Current

-2 mA Maximum

“On” State Voltage Drop

-1.5V Maximum

Surge Current

-5A (1 Sec. Maximum)

Min. Operational Current

-50 mA

Operate Time

-0.5ms Maximum

Reset Time

-2 ms Maximum

Operating Voltage

-110/120V AC 50/60 Hz 100 mA

Temperature Range

-32°F to 125°F (Operating)

0°F to 150°F (Storage)

Outputs

-Same as Programmer

Operating Voltage

-110/120V AC 50/60 Hz 150 mA

Temperature Range

-32°F to 125°F (Operating)

0°F to 150°F (Storage)