Chapter 1: Introduction/Description

Installation and Maintenance Manual

2

The completely self-contained unit can operate up to 30 independent outputs (six standard) based on

the rotary position of the resolver.

It offers an on line fault check which provides an automatic, in-process mechanism to verify that all

major programmable limit switch functions are operating properly. The fault check output can be

energized by activating the fault check enable input. The output is a mechanical relay with 1 N.O. and 1

N.C. contact, which remains energized during normal operation.

A programmable motion detect output will energize a relay when the transducer speed meets or

exceeds the customer-preprogrammed RPM value.

SOFTWARE OPTION “P” ENHANCES THE SYSTEM BY OFFERING:

n

Multiple Programs - Allow storage of job setups for future use. This saves time

spent reprogramming and lessens the chance of programming errors when tooling is

changed.

n

Speed-Induced Offsets - On many variable speed machines, the limit switch outputs

have to be adjusted when the speed increases or decreases. This option automatically

adjusts specified circuits based on speed.

n

Time-Based Outputs - Specified outputs can be programmed to turn on based on

position and turn off based on time (0.01 - 9.99 seconds).

1.3: Controller Features and Functions

The controller is housed in an all metal case that can be panel mounted. The controller consists of a

keypad, a CPU Board, and a Power Supply I/O Board.

The following features are found on the 1995A Micro-Set.

n

Display

A (3) three-digit LED readout and a 10-place bar graph are provided.

The LED readout displays current angular position and/or RPM and

programming details, while the bar graph shows fault check, program

status, and limit status.

n

I/O

Mechanical relays, AC solid-state, and DC solid-state relays are

available, and any combination can be specified. The example in the

catalog shows three AC and three DC solid-state relays being speci-

fied. There is a fixed price adder for any combination of relays other

than all mechanical (6M). The fault check relay will always be a

mechanical relay regardless of the type of output relays specified.

See Chapter 9: Specifications.

NOTE: The Bar graph will not display expansion board relay status.