Chapter 3: Programming

3.21: Time-Based Outputs

(Available Only on Option “P” Units)

These outputs are programmed to turn on based on position and turn off based on a keypad selectable

time interval. Circuits one through six can be selected for this type of operation. Circuits cannot be

programmed for Linear Speed Offset and Time-Based outputs at the same time; thus the total

combined number of Linear Speed Offset and Time-Based outputs cannot exceed six.

NOTE: CIR# 301 thru 306 only enable the circuit so that it can be programmed for a Time-Based

output. After Time-Based circuits are enabled, see Section 3.8: Setpoints.

The Time-Based feature is programmed as follows:

A)

Unit must be in the “Program” mode.

B)

Depress

CIR# 301 represents CIR# 1, CIR# 302 represents CIR# 2, etc. A zero (0) after CIR# 301-

306 means that the circuit will function as a normal limit switch as outlined in Section 3.8:

Setpoints; however, if a one (1) is entered in after CIR# 301-306, it means that the circuit is to

be set up for a position ON and a timed OFF output.

C)

This sequence only enables or disables LS1 thru LS6 for Time-Based operation. After an LS

is enabled as a Time-Based circuit, follow normal programming instructions. See Section 3.8:

Setpoints, C and D.

CIR# - (301 thru 306) -

(0 or 1)

-

-

ENT

ENT .

NOTE: If LS6 is set as a motion detector, it cannot be set for Time-Based.

D)

A Time-Based output may only have one CIR ON and one CIR OFF setpoint. This output

will turn on based upon the CIR ON position data and will turn OFF based upon the CIR OFF

time data, which is displayed and programmed in 0.01 second increments. A Time-Based

output uses three setpoints. See Section 3.7: Setpoint Formula.

E)

Outputs 1 through 6 may incorporate Linear Speed Offset or may be Time-Based. How

ever, no output can be both. In addition, LS6 may be selected to be a motion detect output. If

two or three types of outputs are required, first select the number of Linear Speed circuits

required (CIR 80) and then individually select the Time-Based outputs and Motion Detect

output.

Example:

Outputs 1 & 2 Linear Speed

CIR = 80 - ENT - 2 - ENT

Outputs 3 & 4 Time-Based

CIR = 303 - ENT - 1 - ENT

CIR = 304 - ENT - 1 - ENT

Output 6 Motion Detect

CIR = 55 - ENT - 1 - ENT