Chapter 6: Security Inputs

Chapter 6: Security Inputs

The Run/Program security inputs may be operated by an isolated contact, current sourcing, or a current

sinking device, 5V DC @ 10mA. See Fig 11-3, Chapter 11: Wiring Diagrams.

NOTE: The 1995 PLS cannot be programmed until the security input has been actuated by means of

connections between +5V DC and “Security +” input and between “Security -” input and

ground.

NOTE: If the Run/Security program is not needed (always in the Program mode) install jumper wires

form Pin 9 (+5V DC) to Pin 10 (Security +) and from Pin 11 (Security -) to Pin 14 (GND)

on the 16-place resolver connector.