6. SysEx Messages

32

6 SysEx Messages

The following is a list of the TWEAKER’s factory default MIDI note and CC settings.

6.1 System Exclusive Command Bytes

The System Exclusive message includes the official MIDI Manufacturer ID for ELECTRIX, a Product

number, and the Command number. Each command is described in the following sections.

240, 0, 1, 106, 1, NN, ..., 247

The ELECTRIX identification number is 6A

The TWEAKER product number is 01

The Command number is NN

Note: All numbers in this specification are Base-10 (Decimal) numbers unless otherwise noted.

6.2 Set Messages

These messages allow you to change the settings of the TWEAKER.

01 : Button Mappings

This Message changes the MIDI mapping (Channel, Note/CC, and Number).

Total Bytes:

107

Data Bytes:

100

Data Bytes per Button: 2
1st Data Byte Received: Mapping Number
2nd Data Byte Received: Channel Number/ Output Type

Special Cases:

Encoder Speed Control Button

Output Type = 1

Mapping Number = 127