2

ON position

OFF position

MAIN BURNER VALVE

air shut-

ter

(ring

burners

only)

FIGURE 1

FIGURE 2

OFF position:

turn clockwise

until screw can-

not be turned.

ON position

turn counter-

clockwise

PILOT VALVE

11

Put lit match

to pilot

burner, de-

press & hold

red button

MAIN BURNER VALVE

OFF position

ON position

figure 1

5. UNITS WITH SAFETY VALVES: LIGHTING AND SHUT DOWN INSTRUCTIONS.

Always follow these lighting and shutdown instructions when operating your unit. A five minute

complete shutoff period is required before lighting or relighting pilot. See diagram below.

a) Check that all gas valves on the unit are turned “OFF” (see figure 2: lever handles in horizontal posi-

tion) before turning “ON” main gas line. Check for leaks using soapy water or other suitable leak

detector. DO NOT USE OPEN FLAME FOR TESTING.

b) Main burner valve shall be in “OFF” position. Position a burning match by the pilot burner in the

combustion chamber of the range. Depress the red button on safety control (see fig.1 below) and light

pilot. The pilot should light.

c) Continue to hold the button for one minute or until the pilot stays lit,

SHUT DOWN: For temporary Shut Down turn all burner valves to "OFF" position.

For an extended period of time, turn all burner valves "OFF" and also turn "OFF"

gas supply to the range.

1. The front of the unit must be kept clear to avoid restriction of air supply for combustion.

2. The equipment must be installed with adequate clearance for servicing and proper operation.

3. This unit should be operated only with drip trays in place.

4. UNITS WITHOUT SAFETY VALVES: LIGHTING AND SHUT DOWN INSTRUCTIONS

Be sure that all piping is gas tight and all air purged from the lines. With main burner valve in “OFF”

position (see fig.2), using a screw driver turn pilot screw counter clockwise to “ON” (see fig.1 below)

and light pilot located in the combustion chamber. Make sure the pilot stays lit. All units are equipped

with fixed orifices which cannot be adjusted for gas flow. Ring burners have adjustable air mixers to

adjust the air/gas mixture.

Turn right hand burner valve to full “ON” position (see fig.2 below) and adjust air shutter until proper

blue flame is burning on both inner rings. Repeat operation for left hand valve only if your range is

equipped with three ring burners.

SHUTDOWN:

Turn burner valves to "OFF" position (see fig.2) and turn the pilot screw clockwise (see fig. 1) until it

cannot be turned further. Repeat this step for each chambers.