73 appendix i – Aalborg PWE Digital User Manual

Page 78

Advertising
background image

73

APPENDIX I

AALBORG

7 PWE Flow Meter EEPROM Variables Rev:A002 [10/01/2009]

Note: indexes 0-19 are write protected (manufacture and calibration specific data)

INDEX

NAME

DATA TYPE

NOTES

0

BlankEEPROM[10]

char[10]

Do not modify. Table Revision [PROTECTED]

1

SerialNumber[20]

char[20]

Serial Number [PROTECTED]

2

ModelNumber[20]

char[20]

Model Number [PROTECTED]

3

SoftwareVer[10]

char[10]

Firmware Version [PROTECTED]

4

ManufReservedF1

float

Manufacture Specific float data [PROTECTED]

5

ManufReservedF2

float

Manufacture Specific float data [PROTECTED]

6

MeterCalFactorM

float

Manufacture Assigned Number of Pulses per Gallon
[PROTECTED]

7

MeterSize

float

Size of the meter’s flow tube [mm] [PROTECTED]

8

ReservedText[12]

char[12]

Reserved for Manufacture Specific Text Info
[PROTECTED]

9

ManufReservedF3

float

Manufacture Specific float data [PROTECTED]

10

ManufReservedF4

float

Manufacture Specific float data [PROTECTED]

11

ManufReservedF5

float

Manufacture Specific float data [PROTECTED]

12

ManufReservedF6

float

Manufacture Specific float data [PROTECTED]

13

ManufReservedUI1

uint

Manufacture Specific uint data [PROTECTED]

14

ManufReservedUI2

uint

Manufacture Specific uint data [PROTECTED]

15

ManufReservedUI3

uint

Manufacture Specific uint data [PROTECTED]

16

ManufReservedUI4

uint

Manufacture Specific uint data [PROTECTED]

17

ManufReservedSI1

int

Manufacture Specific int data [PROTECTED]

18

ManufReservedSI2

int

Manufacture Specific int data [PROTECTED]

19

ManufReservedSI3

int

Manufacture Specific int data [PROTECTED]

20

TimeSinceCalHr

float

Time elapsed since last calibration in hours

21

ProtectionCode

uint

Program Parameters Protection Code [0-255]

22

BackLight

int

Back Light Level [0-4095]**

23

BackLightMode

int

Back Light Mode (E-Enable/D-Disable)**

24

LCD_Diagnostic

uint

LCD Diagnostic Mode: [0, 1]

25

Address485

char[4]

Two hexadecimal characters address for RS485
only [01-FF]

26

FlowUnits

int

Current Units of Measure [0-28]

27

AlarmMode

uint

Flow Alarm Mode (0=Disabled, 1=Enabled)

28

LowAlarmPFS

float

Low Flow Alarm Setting [%FS] 0-Disabled

29

HiAlarmPFS

float

High Flow Alarm Setting [%FS] 0-Disabled

30

AlmDelay

uint

Flow Alarm Action Delay [0-3600sec] 0-Disabled

31

RelaySetting

char[4]

Relays Assignment Setting**

32

TotalMode

uint

Totalizer Mode [1- Enabled, 0 - Disabled]

Advertising