maIntenance

replacing the ultra filter cartridge

1. Open the faucet or tap closest downstream to the

filtration system.

2. Close the Inlet Water Valve and allow the system

to depressurize.

3. Place a bucket under the strainer at the inlet

connection to the system. Open the strainer by

unscrewing the cap. Water will flow out of the

strainer as the system drains.

4. Press the

flusH button to help drain the system.

5. Reattach the cap on the strainer when the water

flow stops. Unplug the power cord.

6. Disconnect the Inlet Port and Drain Port

Connections.

7. Disconnect the Permeate Port Connection.

8. Using a screwdriver, remove the screws from the

Cartridge Bracket and set the bracket and screws

aside.

9. Unscrew the elbows at the Inlet and Drain Ports of

the cartridge. Set the elbows and fittings aside.

10. Using thread seal tape and pipe dope, attach the

elbows and fittings to the new cartridge. Make

sure the drain solenoid valve is attached to the

drain end and the inlet strainer is attached to the

inlet end.

nOte: Do nOt overtighten the elbows on to the

cartridge.

11. Install the new cartridge with fittings attached

using the cartridge bracket and screws from Step 8.

12. Inspect the O-rings and seals to ensure they

are clean and not splitting or cut. For all O-rings

and seals, ensure they are lubricated with an

approved food grade lubricant acceptable for

drinking water use.

13. Connect the Permeate Port Connection.

figure 5. replacing the ultra filter cartridge

cartridge

bracket

cartridge

end cap

permeate

port

connection

14. Reattach the Inlet Port and Drain Port

Connections.

15. Plug in the power cord.

16. Open the Inlet Water Valve and allow the system

to pressurize.

17. Rinse the new Ultra Filter Cartridge before

placing the system back into operation. Follow

the

rinsing the Ultra Filter Cartridge and

sanitizing the system and lines procedures in

the Installation section of this manual to complete

the cartridge change.

18. When rinsing is complete, repressurize the

system.