UF-216CC water Filtration system

16

A.J. Antunes & Co.

P/N 1011135 Rev. A 03/12

trOublesHOOtInG

problem

possible cause

corrective action

Unit does not have power.

The power cord is not correctly

plugged in.

Plug power cord in correctly.

The Control Display is blank.

The power cord is not correctly

plugged in.

Plug power cord in correctly.

Control Board is inoperable.

Contact your maintenance person or

Authorized Service agency.

Transformer is inoperable.

No water comes out of the fil-

ter system

Inlet Valve closed

Open the Inlet Valve

Inlet Strainer is plugged

Clean/replace Inlet Strainer

End of the capillaries plugged

Clean/replace Ultra Filter Cartridge

Low water flow/pressure out

of system

See above.

See above.

The system may be in a flush cycle.

Wait for the flush cycle to end.

Flushing program not set correctly

for water conditions.

Decrease the flush interval (refer to the

Operation section of this manual).

Drain Valve is stuck open.

Replace/rebuild the Drain Valve.

The inlet water pressure is too low.

Boost the inlet water pressure/replace

pipes.

Water tastes bad.

Storage/shipping solution not com-

pletely rinsed out of system.

Rinse system for a longer period of time.

Biological growth in pipes.

Sanitize plumbing.

Water conditions changed.

Consider installing additional filtration.

Broken capillary in Filter Cartridge.

Replace Filter Cartridge.

Flush runs continuously.

Drain Valve stuck open.

Replace/rebuild the Drain Valve.

Controller sending continuous signal

to valve.

Replace the controller.

Flush occurs at time of high

water usage.

The Flush Interval is set to interfere

with water use.

Change Flush Interval. Unplug unit and

plug in at a time of lower water usage.

Water splashes at drain dur-

ing flush.

Drain line not positioned properly.

Reposition the end of the drain line.

Water leaks at the ends of the

Filter Cartridge after changing

cartridges.

Cartridge end connections are not

tight enough.

Tighten with wrench if necessary.

Water leaks from Permeate

port.

Permeate port is not tight enough

Tighten, with wrench if necessary.

O-ring not lubricated.

Lubricate O-ring with food-grade lubricant.

O-ring split, cut, or twisted.

Replace O-ring.

Water leaks from system fit-

ting or connection.

Fitting broken or loose.

Retighten or replace the fitting.

Not enough pipe thread sealant

used.

Redo the fitting with the proper amount of

sealant.