maIntenance (continued)

changing the Interval setting

resetting the timer program

During the normal operation, the system will flush

according to the set interval. It is possible the system

will flush at a time of high water use. If this poses a

problem, the controller can be reset. Unplug the power

supply, wait for 5 seconds, and then plug the power

supply in. When power is restored to the controller, it

will automatically enter Flush Mode. The controller will

then begin timing from the point when power is restored

based on the interval setting selected.

figure 7. controller

flush

Interval

button Hold time button

leD

flush

leD

15 minutes

A

10 seconds

On

On

30 minutes

B

10 seconds

On

On

45 minutes

C

10 seconds

On

On

1 hour

A

5 seconds

On

Off

4 hour

B

5 seconds

On

Off

6 hours

C

5 seconds

On

Off

12 hours

D

5 seconds

On

Off

24 hours

D

10 seconds

On

On

cautIOn

changing the flush interval can cause the ultra

filter to plug prematurely and may void the war-

ranty. consult the factory for more information.

Though not recommended, the Interval Setting on the

controller can be changed. If the setting must be

changed, use the chart below. Press and hold the cor-

responding button. After 5 seconds, the Button leD will

turn on. After 10 seconds, the Flush leD will also turn

on.