UF-216CC water Filtration system

7

A.J. Antunes & Co.

P/N 1011135 Rev. A 03/12

OVerVIew

Overview

The UF-216CC system operates in two modes:
• Normal Operation Mode
• Flush Mode
During Normal Operation Mode, water enters the Inlet

and flows through the Ultra Filter before exiting the

Permeate Outlet as usable product water.

During Flush Mode, the Drain Valve opens and water

entering the Inlet flushes and cleans the Ultra Filter

membrane by removing any debris collecting on the

membrane wall.

The Drain Valve is only powered during Flush Mode.

nOte: Do nOt unplug the power cord or turn off

the system during flush mode. If there is a power

outage or the system is unplugged, water will con-

tinue to be filtered but the system will nOt flush.

this could cause the ultra filter to plug premature-

ly and may void the warranty.

The flush is automated by the controller to last 10

seconds and take place in one hour intervals. This

interval can be changed (see

Changing the interval

setting in the Maintenance section of this manual).

manual flushing

A manual flush can be activated at any time by pressing

the

flusH button.

When the

flusH button is pressed, the Flush leD on

the controller flashes and the Drain Valve opens for 10

seconds. After flushing is complete, the Drain Valve will

close, the Flush leD will stop flashing and the unit will

automatically return to Normal Operation Mode.

nOte: a manual flush will not affect the interval

flush setting.

cautIOn

changing the flush interval can cause the ultra

filter to plug prematurely and may void the war-

ranty. consult the factory for more information.