unpacking

1. Remove the system and all packing materials

from the shipping carton.

2. Remove all packing materials and protective

coverings from the system

3. Remove the information packet. To prevent any

delay in obtaining warranty coverage, fill out and

mail the warranty card.

nOte: If any parts are damaged, contact a.J.

antunes & co. ImmeDIately at 1-800-253-2991 or

1-630-784-1000.

InstallatIOn

plumbInG

nOte: this unit is designed to use tap water not to

exceed 100°f (38°c) or 100 psig (690 kpa).

The UF-216CC system uses the following connections

(Figure 1):

• Water Inlet

1/2” NPT

• Permeate (Product Water)

1/2” NPT

• Drain

1/2” NPT

When making a plumbing connection to the system,

remember to use a back-up wrench on the supporting

plumbing. Always use a good quality, approved pipe

sealant or thread seal tape on pipe threads. Be careful

not to get the pipe sealant inside the pipe when making

the connections.

Do NOT over tighten the connections. It is recom-

mended that plastic fittings be used when connecting to

the plastic connections of the system. This will reduce

the possibility of cracking the connections due to over-

tightening.
If soldered plumbing is used, do NOT apply heat to,

or near, the filtration system. The use of union (O-ring

seal) connections is highly recommended for ease of

installation and future servicing.

cautIOn

this equipment is to be installed to comply with

the basic plumbing code of the building Officials

and code administrators, Inc. (bOca) and the

food service sanitation manual of the food and

Drug administration (fDa).

cautIOn

water pressure must not exceed 100 psig (690

kpa). to reduce water pressure, install a water

pressure regulator and set water pressure to suit

application. note that the trans membrane pres-

sure must not exceed 45 psi (310 kpa).

equipment setup

General

When placing the unit into service, pay attention to the

following guidelines:
• Do NOT immerse cord or plug in water.

• Keep cord away from heated surfaces.

suGGesteD tOOls anD supplIes fOr InstallatIOn

The following tools and supplies are suggested to make

the installation easier:

• Screwdriver

• Drill with bits

• Tape measure

• Pipe wrenches

• Adjustable wrenches

• level

• Two gallon bucket

• Pipe dope or thread seal tape

• Fresh 5 1/4% liquid chlorine

bleach

electrIcal

Ensure that the line voltage corresponds to the stated

voltage on the units specification label. Make sure that

the plug on the power cord from the system and the

outlet match. For proper operation, and to ensure the

highest quality water from the system, make sure that

the system is not connected to a switched electrical

outlet.

ImpOrtant

commonwealth of massachusetts plumbing code

248 cmr shall be adhered to. the use of saddle

valves are not permitted, please consult your local

plumber.