Uf-216cc water filtration system, Maintenance (continued), A.j. antunes & co – A.J. Antunes & Co UF-216CC 9700407 User Manual

Page 14

Advertising
background image

UF-216CC water Filtration system

14

A.J. Antunes & Co.

P/N 1011135 Rev. A 03/12

maIntenance (continued)

rinsing and replacing the carbon element

1. Open the faucet or tap closest downstream to the

filtration system.

2. Close the inlet water valve and allow the system

to depressurize.

3. Place a bucket under the strainer at the inlet

connection to the system. Open the strain by

unscrewing the cap. Water will flow out of the

strainer as the system drains.

4. Press the

flusH button to help drain the system.

5. Reattach the cap on the strainer when the water

flow stops. Unplug the power cord.

6. Press and hold the ReD Pressure Relief Button

on the top of each of the Carbon Element Housing

to lower the water level inside the housing by 2 to

3 inches.

7. Remove the Carbon Element Housing.
8. Empty any water into a drain and discard the old

Carbon Element.

9. Inspect the O-ring on the Carbon Element

housing (Figure 6). Replace the O-ring if it is

cracked, twisted, or missing.

10. Lubricate the O-ring with an approved food grade

lubricant and install into the Carbon Element

Housing.

11. Install the new Carbon Element into the Carbon

Element Housing.

nOte: make sure the Gasket remains in place in

the recessed grooves on both ends of the carbon

element.
12. Screw the Carbon element housing (containing

the Carbon Element) into place on the Carbon

Element Head. The Housing will come to a hard

stop at the end of the thread. Use a Filter Wrench

if necessary.

nOte: Do nOt overtighten the carbon element

Housing.
13. Plug in the power cord.
14. Open the inlet water valve and allow the system

to pressurize.

15. To help remove trapped air from the Carbon

element housing, press the ReD Pressure Relief

button on the top of the Housing until water just

begins to come out.

16. Rinse the Carbon Element for at least 5 minutes.
nOte: Do nOt consume the water used for rinsing

the carbon element.
17. The system is now ready for use.

figure 6. replacing the carbon cartridge

carbon

Housing

carbon

cartridge

system sanitization

The system and downstream plumbing should be sani-

tized at least once a year. When necessary, follow the

procedure in

sanitizing the system and lines in the

Installation section of this manual.

Advertising