Features in 275-04, Level 1, Level 2 – Allied Telesis AR700 Series User Manual

Page 13

Advertising
background image

Features in 275-04

13

Version 275-05
C613-10473-00 REV D

Features in 275-04

Software Maintenance Version 275-04 includes all resolved issues and enhancements in earlier versions, and the resolved issues and enhancements in the
following tables. In the tables, for each product series:

“Y” in a white column indicates that the resolution is available in Version 275-04 for that product series.

“-” in a white column indicates that the issue did not apply to that product series.

a grey-shaded column indicates that Version 275-04 was not released on that product series. “Y” in a grey column indicates that the issue applied to that
product series and is resolved in the next Version released on that product series (275-05).

Level 1

No level 1 issues

Level 2

CR

Module

Level

Description

AR

4

0

0

AR

7

x

5

A

R

7

50S

Ra

p

ie

r

i

A

T

-8

800

A

T

-8

600

A

T

-8

700

X

L

A

T

-8

948

A

T

-9

900

A

T

-9

800

CR00007928

Switch

2

If a user entered the command set vlan=default port=port-number
frame=tag and saved the configuration with the create config command while
MSTP was enabled, the resulting configuration file sometimes did not contain the
changes. Therefore, rebooting the switch removed the changes.

This issue has been resolved.

-

-

-

Y

Y

Y

-

Y

Y

-

CR00007950

SSH

2

When a user is logged into the router or switch via an ASYN port and uses the
SSH client to send a command to a remote SSH server, the server sends the
response and the SSH session is closed as expected. However, the tail end of the
response was sometimes not received by the user logged into the ASYN port.

This issue has been resolved.

Y

Y

Y

Y

Y

Y

-

Y

Y

Y