background image

Features in 275-02

35

Version 275-05
C613-10473-00 REV D

CR00010166

Port

Authentication

2

When the supplicantmac parameter was used in the reset
portauth=[macbased] port
command to specify the supplicant to reset, all
supplicants were removed from the router or switch’s forwarding database,
instead of only the specified supplicant.

This issue has been resolved.

Y

Y

Y

Y

Y

Y

Y

Y

Y

-

CR00010168

BGP

2

When BGP damping was enabled, the damping history of withdrawn routes was
not maintained correctly.

This issue has been resolved. The damping history is now maintained until the
route returns, or until the damping history times out and the route is deleted.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00010169

BGP

2

When a route’s attribute was updated in the BGP route table, a damping record
was not created in the history.

This issue has been resolved.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00010202

Switch

2

Previously, the polarity was incorrectly showing MDI instead of MDI-X in the
output of show switch port=port-number.

This issue has been resolved.

-

-

-

-

-

-

-

Y

Y

-

CR00010219

RADIUS

2

When using telnet login authentication with a RADIUS-backup User (RBU), the
router or switch sometimes rebooted.

This issue has been resolved.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00010223

OSPF

2

BGP routes imported into OSPF are now advertised in external LSAs as metric type
2.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00010226

QoS

2

When creating or setting QoS traffic classes, the exceedaction and
exceedremarkvalue parameters were erroneously rejected.

This issue has been resolved.

-

-

-

Y

Y

Y

Y

-

-

-

CR

Module

Level

Description

A

R

400

A

R

7x5

A

R

750

S

Ra

p

ie

r

i

AT

-8

8

0

0

AT

-8

6

0

0

A

T

-87

00X

L

AT

-8

9

4

8

AT

-9

9

0

0

AT

-9

8

0

0

Advertising